Thermal ablation of thyroid nodules: are radiofrequency ablation, microwave ablation and high intensity focused ultrasound equally safe and effective methods?
Objectives: This study compares volume reduction of benign thyroid nodules three months after Radiofrequency Ablation (RFA), Microwave Ablation (MWA) or High Intensity Focused Ultrasound (HIFU) to evaluate which of these methods is the most effective and safe alternative to thyroidectomy or radioiodine therapy.
Material and methods: Ninety-four patients (39 male, 55 female) with a total of 118 benign, symptomatic thyroid nodules were divided into three subgroups. HIFU was applied to 14 patients with small nodules. The other 80 patients were divided up into two groups of 40 patients each for RFA and MWA in the assumption that both methods are comparable effective. The pre-ablative and post-ablative volume was measured by ultrasound.
Results: RFA showed a significant volume reduction of nodules of 50 % (p<0.05), MWA of 44 % (p<0.05) and HIFU of 48 % (p<0.05) three months after ablation. None of the examined ablation techniques caused serious or permanent complications.

Korkusuz, Y., Gröner, D., Raczynski, N., Relin, O., Kingeter, Y., Grünwald, F., & Happel, C. (2017). Thermal ablation of thyroid nodules: are radiofrequency ablation, microwave ablation and high intensity focused ultrasound equally safe and effective methods? European Radiology, 28(3), 929–935. doi:10.1007/s00330-017-5039-x